Inrush currents tend to be asymmetrical when viewed on an oscilloscope. Such relays are less sensitive because they cannot make correct distinction between heavy load conditions and minor fault conditions. Should a fault occur inside the zone of relay protection that is between the cts, the differential relay would receive current in the operating coil. Differential relay current differential relay biased.
Red615 is a phasesegregated, twoend, line differential protection and control relay for protection, control, measurement and supervision of overhead line and cable feeders in utility and industrial power distribution networks, including radial, looped and meshed distribution networks, with or without distributed generation. Pdf line current differential protection automation and. The differential protection of transformer has many advantages over other schemes of protection. Differential relay current differential relay biased beam. Keywordsdifferential current, protection, restraining voltage, stability, current transformer.
Bus under voltage protection armature shown in the nonenergized trip position normally. From a design perspective, the distributed nature of the. The ratio of the current transformers are so chosen, the secondary currents of both current. But the effect of even a rare fault may be very serious for a power transformer. Siprotec protection relays figure 1 shows a simple differential protection scheme, also known as a merzprice scheme. In part ii of the paper we propose a new approach for transformer differential protection and describe the relay that is based on this approach. One main difference between the pilot wire relay and the digital current differential relay is the. This indicates that in this case a symmetrical fault current will produce a higher peak than an offset current. Jul 07, 2019 such a condition would occur for a shortcircuit fault outside the zone of relay protection. Pdf line protection in breakerandahalf configurations requires main protection functions to respond to the sum of the two currents. End result is spurious differential current appearing in the summation of the.
Transformer protection application guide this guide focuses primarily on application of protective relays for the protection of power transformers, with an emphasis on the most prevalent protection schemes and transformers. Pdf application of distance and line current differential relays in. The principles of differential protection you must understand on photo. Pdf a currentbased solution for transformer differential. Sel387 current differential and overcurrent relay protection protect power transformers with as many as four windings using. The differential dc current relay is designed to monitor it sys tems for insulation deterioration. Externally earthed system with multiple generators g 87g 51n.
The principles of differential protection you must understand. Fundamental overcurrent, distance and differential. Differential current protection of transformer using arduino. Current mismatch caused by the transformation ratio and differing ct ratios. The outputs from the respective current transformers are thus 4. Types hu, hu1 transformer differential relays class 1e. A new design for the digital line current differential relay is presented. Line current differential protection automation and control system. Sep 08, 2016 observation of ref stability are as under.
Pilot wire differential relays device 87l distance. Differential protection of yy and connected power transformer mayurdhvajsinh p. Use overcurrent elements from combined ct inputs for backup protection. History of low impedance bus differential and the evolution of the unrestrained element the earliest differential relays were differentially connected induction disc time over. A clever solution to the problem of false 87 relay tripping due to transformer inrush current is called harmonic restraint or harmonic blocking. In current differential relay two current transformers are fitted on the either side of the equipment to be protected. Voltage applied hv rph 230v measured current hv ct differential core 12ma hv nct current 12ma current measured at hv ref relay terminal 0. Multiwinding current differential protection apply the sel387 relay for protection of two, three, or fourwinding power transformers. Applying sel differential relays introduction to transformer differential protection explain challenges of transformer differential protection understand need for tap, phase, and zerosequence compensation and how they work. Pdf advanced line current differential protection with reduced. In this type of relay, there are restraining coils in addition to the operating coil of the relay. Principles of differential relaying current balance high impedance also known as unbiased differential protection only one actuating relay quantity current required for operation. Pdf line current differential protection creates challenges for relay design and application.
Pdf easy method for testing transformer differential relays. The aim of this this technical article is to cover the most important principles of four fundamental relay protections. A model of a differential protection relay citeseerx. Differential protection of a transformer the transformer is one of the major equipment in power system. The transformer needs to generate a ground current of at least 50% of generator rated current to provide about 95% or more winding coverage.
The differential relay works on the principle of comparison between the phase angle. Bus protection considerations for various bus types. The following protection functions are used in this relay. A highimpedance differential relay forms an operating quantity by connecting zone cts in parallel with a resistive element. An arrangement of overcurrent relay connected to operate as a differential relay is shown in the figure below. On heavy external faults where a main current trans. Differential current that is transient in nature transient. Line differential protection and control red615 ansi feeder. The differential relays normally response to those faults which occur in side the differential protection zone of. Understanding and testing the abb red670 distanceline. In this simple scheme, we can assume that under normal operating conditions, the current entering into the piece of equipment under protection is equal. Differential protection is based on kirchhoffs laws, stating that all current into a network node shall add up to 0 in an ideal system. The corresponding lv secondary current referred to the hv side, taking into account the maximum tap position of 15%, is 6.
If the line current transformers do not saturate and the correct ratio matching taps applied, no effective current flows in the operating transformer of the relay. Differential current protection of transformer using. In the current differential scheme, there are two sets of current transformer each connected to either side of the equipment protected by differential relay. Buses are typically protected by either highimpedance differential relays or restrained low percentageimpedance differential relays. Highimpedance differential applications with mismatched cts. It implies that a large differential current is required for an. Differential protection schemes mainly, the concern is false differential current caused by ct saturation. This function is substantially more sensitive than the differential protection during faults to earth in a winding, detecting fault currents as small as 10 % of the transformer rated current. The ddca is able to selectively indicate faults in branched.
The relay trips the bus when it detects excessive differential current. The ratio of the current transformers are so chosen, the secondary currents of both current transformers matches each other in magnitude. Pdf line protection in breakerandahalf configurations requires main protection. From figure 2, a percentage bias of 20% would ensure stability for this condition. This maloperation is caused by a spill current due to the impact of on load tap changer oltc. The faults occur in the transformer inside the insulating oil can be detected by buchholz relay. Explain challenges of transformer differential protection understand need for tap, phase, and zerosequence compensation and how they work understand how transformer differential relays are made secure for inrush and overexcitation transformer differential protection presentation objectives.
Redundant bus protection using highimpedance differential relays. Data sheet multi differential protection relay, mdr2 principle diagram, option c4 ac current measurement secondary side ac current measurement secondary side ac current measurement primary side ac current measurement primary side. Line differential protection substation automation. The main source of steadystate differential current is the magnetizing branch of the transformer equivalent circuit. Ece 525 session 3, page 11 power systems protection and relaying fall 2018 ansiieee standard device numbers in north america protective relays are generally referred to by standard device numbers. Current differential line protection setting consideration. When a differential current above the set limit is detected, one. L over current l differential l backup l under voltage. Hence, only a contactopening torque is produced on the differential unit.
Differential connected overcurrent backup configuration consists of a high impedance bus differential relay and an overcurrent relay connected in a series configuration. It is available in eight versions, five of these versions each with reconnecting operate values u s1 and u s2, and three versions with continuously settable operate value between 100 and 400 v. As the name suggests, one of the main functions provided by the relay is zdistance protection 21 or impedance protection. Setting procedures are only discussed in a general nature in the material to follow. Differential is generally applied for both pilot wire relays and digital current differential relays. At normal conditions and for external fault at f, ct 1 and ct 2 circulate currents at their secondarys i s1 and i s2 i s1 i s2 and no current flow through the relay. Nov 01, 2016 a differential relay is defined as the relay that operates when the phase difference of two or more identical electrical quantities exceeds a predetermined amount. It is assumed with these schemes that a certain degree of ct saturation is possible under throughfault conditions.
Consequently, the instantaneous overcurrent relay trips because the value of the differential current i. The term current differential is generally applied for both pilot wire relays and digital current differential relays. It is a static device, totally enclosed and usually oil immersed, and therefore the fault occurs on them are usually rare. In order to match these two current values, so that no relay differential current flows under healthy conditions, an interposing ct will be required to adjust the main line ct output of 3. Biaseddifferential protection theory and application eep. Twowinding current differential protection sensitive current differential protection with programmable single or dualslope percentage restraint, supervised by the second and fifthharmonic elements for secure differential protection on twowinding apparatus. The differential protection of power transformer is a unit protection scheme. This is designed to response to the differential current in the term of its fractional relation to the current flowing through the protected section. Phase comparison relays are line differential relays mainly intended for used with power line carrier. Numerical relays are based on the use of microprocessors. A relay which senses and operates the phase difference between the current entering into the electrical system and the current leaving the electrical system is called a current differential relay. One main difference between the pilot wire relay and the digital current differential relay is the communication medium used. The siprotec 7sd828687 line differential protection have been designed particularly for the selective protection of overhead lines and cables with singleended and multiended infeed in mediumvoltage and highvoltage systems.
The example differential protection relay shown in the below figure is a transformer differential. Oct 02, 2016 learn the basics of differential protection of transformers. Differential relays can detect such type of faults. Current differential protection another common form of protection for apparatus such as transformers, generators, busses and power lines is. The example differential protection relay shown in the below figure is a transformer differential relay. When the power is connected to a1 and a2, and with no differential current through the sensing coil, the green leds for differential and relay on normal function will be on. All protectiverelay types are derived either directly from these basic elements, by. Microprocessor based restrained low impedance bus differential elements. Moreover buchholz relay is provided in transformer for detecting any internal fault in the transformer but differential protection scheme detects the same in more faster way. Figure 5 differential circuit using a simple overcurrent relay if there is no saturation, the differential current id will be zero and there will be no tendency for the relay to operate. May 15, 2018 generally differential protection is provided in the electrical power transformer rated more than 5mva.
Twowinding differential protectionprovide current differential protection with programmable single or dualslope percentage restraint for twowinding transformers, reactors, generators, large motors, and other twoterminal apparatus. Sel587 current differential relay schweitzer engineering. Impedance stabilized differential relays place intentional impedance in the. Line current differential relay response to a direct. Thus, the relay trip the main circuit breakers on both sides of. Unrestrained lowimpedance bus differential should i use it. A pair of identical current transformers are fitted on either end of the section to be protected alternator winding in this case. Easy method for testing transformer differential relays. This paper carries the idea of selection of dual slope differential relay parameters for various faulty conditions on the system. Learn the basics of differential protection of transformers. Most of the relays discussed so far relied on excess of current for their operation. Jun 08, 2019 in the current differential scheme, there are two sets of current transformer each connected to either side of the equipment protected by differential relay. Protective relays, associated communication systems, voltage and current sensing devices. A currentbased solution for transformer differential.
An overcurrent relay 51n or a differential relay 87g gives the protection for each generator. The principles of differential protection you must. A big difference between conventional electromechanical and static relays is how the relays are wired. Abstractline current differential protection creates challenges for relay design and application. The 800168 relay is designed for use with threewinding transformers, and has three through current restraint circuits and one differential current circuit. Differential protection what goes in must come out. Percentage restrained differential, percentage of what. A differential relay is defined as the relay that operates when the phase difference of two or more identical electrical quantities exceeds a predetermined amount. This limits the current supplied, and the relay operates only on the slower part of its time current curve. Line current differential relay characteristic 1 type a line current differential relay the type a line current differential relay is designed to protect two or threeterminal transmission lines and has a. The relays are connected together with a twoconductor pilot wire. Modern line current differential protection solutions.
It may also be used for four circuit transformer protection figure 9 when only three. Power systems protection and relaying ansiieee standard. Electromechanical and static relays have fixed wiring and the setting is manual. Furthermore, this relay contains a highimpedance differential protection input.
The external stabilizing resistor supplied with the relay allows continuous adjustment of the relay voltage setting over a wide range. Overcurrent relay the differential circuit using a simple overcurrent relay is shown in figure 5. Sources of steadystate differential current steadystate differential current is not proportional to through current. Page 5 with the introduction of microprocessor based relays the restrained low impedance bus differential relay came into popular use. The most common bus differential relays use either highimpedance or lowimpedance differential elements. The mdr2 is a stateoftheart combined differential protection and shortcircuit protection relay for generator protection against internal short circuits leaking currents. Medium voltage products technical guide protection criteria. L to limit current through relay to differential unit. For example, consider the same conditions of es 260 and maximum symmetrical fault current of 200 amperes, we get 540 volts per disk from figure 3 and 490 volts per disk from figure 4. One main difference between the pilot wire relay and the digital current differential relay. General equation of phase and magnitude comparators, duality of comparators, electromagnetic relays, over current relays directional relays, distance relay impedance, reactance and mho type, differential relays. Even in cases of fail tripping, the mdr2 offers an adjustable tripping characteristic function that compensates for unbalanced current measurements, avoiding fail.
With the relay connected as shown in the schematic diagram of figure 9a, an external fault causes currents to flow in the airgap restraint transformers of the differential unit. In electrical engineering, a protective relay is a relay device designed to trip a circuit breaker when a fault is detected 4 the first protective relays were electromagnetic devices, relying on coils operating on moving parts to provide detection of abnormal operating conditions such as over current, overvoltage, reverse power flow, overfrequency, and underfrequency. Relay classification, principle of different types of electromagnetic relay. A highimpedance differential relay can be microprocessorbased or electromechanical, and this paper makes no. Understanding and testing the abb red670 distanceline differential relay 10 introduction before starting the relay distance relays 87l2167n are used in line protection and cable protection schemes. Any differential current relay will naturally see this difference as a fault, and may trip power to the transformer unnecessarily. Comprehensive overcurrent protectionapply individual winding phase, residual, and negativesequence.
Consists of two high impedance bus differential relay voltage elements connected in a parallel configuration. Numerical relays protection and control products for. Transformers and compensating coils in the protection range are also possible. T60 percent differential calculations ge power management 3 slope 2 identifies the slope where the ct saturation are likely and maximum restraint is required. The 800168 relay is designed for use with threewinding transformers, and has three throughcurrent restraint circuits and one differential current circuit. Differential protection of transformer differential relays. Modern line current differential protection solutions hank miller and john burger, american electric power normann fischer and bogdan kasztenny, schweitzer engineering laboratories, inc. If fault occurs at point f within the protected zone internal fault as shown in fig. High impedance differential relay radha 1mrk 509 015ben page 2 design the radha relay is part of the combiflex family. An alternative principle for line protection that is quickly becoming the norm is differential protection.